93 research outputs found

    Optical Coherence Spectro-Tomography by all-Optical Depth-Wavelength analysis

    Full text link
    Current spectroscopic optical coherence tomography (OCT) methods rely on a posteriori numerical calculation. We present an alternative for accessing optically the spectroscopic information in OCT, i.e. without any post-processing, by using a grating based correlation and a wavelength demultiplexing system. Conventional A-scan and spectrally resolved A-scan are directly recorded on the image sensor. Furthermore, due to the grating based system, no correlation scan is necessary. In the frame of this paper we present the principle of the system as well as first experimental results

    Analysis of optical filtering in waveguides with a high index modulation using the extended coupled mode theory by hybridization of a matrix method

    No full text
    International audienceIn this paper the authors present an hybrid approach for the analysis of the optical filtering function in corrugated waveguide filters with a high index modulation. This approach is based on the hybridization of the extended couple mode theory (CMT) with the transfer matrix approach. The authors chose to treat the case of high index corrugation because in this case the theory elaborated before is not rigorously applicable. The proposed approach allows the calculation of the reflection coefficient and the full width at half maximum (FWHM) for any index modulation scheme. The hybridization of both methods mentioned above explains the impact and effects of opto-geometric parameters on the reflection coefficient and the bandwidth at mid-height. The theoretical results are verified by experimental measurements realized on Ti:LiNbO3 waveguides with a high index modulation experimentally implemented by engraving using Focused Ion Beam (FIB) process

    Measurement of the Wingbeart Frequency of the Aedes aegypti PROVENIENTS FROM A REGION OF VENEZUELA

    Get PDF
    In order to develop intelligent traps as vector control mechanisms for the prevention and reduction of metaxenic diseases, a physiological parameter is determined as the wingbeat frequency used for later characterization by genus of the Aedes aegypti mosquito in Venezuelan strains. For this, acoustic records were made with wild samples collected in rainwater reservoirs and emerged under controlled conditions in the laboratory. The recordings were made during one minute, in more than a hundred mosquitoes of this species and in both sexes, using a particle speed microphone connected to the audio input of a portable computer and a specialized program for acoustic records. A spectral analysis of the samples was carried out, determining that the average fundamental frequency of flutter for females corresponded to 454.78 ± 55.19 Hz and for males 688.39 ± 40.82 Hz, concluding that the groups were very separated in Its fundamental frequency, with which this parameter is a characteristic that can be used for the detection and classification of mosquitoes of this species, using artificial intelligence in capture devices for vector monitoring and control

    CODIFICADOR 2D DE POSICIÓN, DESPLAZAMIENTO Y ORIENTACIÓN,UTILIZANDO UN PATRÓN DE REFERENCIA PERIODICO Y LA TRANSFORMADA DE FOURIER

    Get PDF
    En este trabajo se muestra un método que permite la medida en el plano 2D, conalta precisión de la posición, el desplazamiento y la orientación de un objeto móvil.Un plano de referencia es fijado a la superficie del objeto y es localizado en laescena por medio de un sistema de imagen estático con resolución subpixel en elplano perpendicular al eje óptico. El uso de la transformada de Fourier 2D, asociadoa la aproximación del plano de fase permiten alta resolución del sistema. Laintroducción de un defecto en el patrón de referencia permite la determinación de laorientación del objeto en un rango de ±180o, sin afectar la precisión y resolución enla localización del objeto

    N-glycosylation of mouse TRAIL-R and human TRAIL-R1 enhances TRAIL-induced death.

    Get PDF
    APO2L/TRAIL (TNF-related apoptosis-inducing ligand) induces death of tumor cells through two agonist receptors, TRAIL-R1 and TRAIL-R2. We demonstrate here that N-linked glycosylation (N-glyc) plays also an important regulatory role for TRAIL-R1-mediated and mouse TRAIL receptor (mTRAIL-R)-mediated apoptosis, but not for TRAIL-R2, which is devoid of N-glycans. Cells expressing N-glyc-defective mutants of TRAIL-R1 and mouse TRAIL-R were less sensitive to TRAIL than their wild-type counterparts. Defective apoptotic signaling by N-glyc-deficient TRAIL receptors was associated with lower TRAIL receptor aggregation and reduced DISC formation, but not with reduced TRAIL-binding affinity. Our results also indicate that TRAIL receptor N-glyc impacts immune evasion strategies. The cytomegalovirus (CMV) UL141 protein, which restricts cell-surface expression of human TRAIL death receptors, binds with significant higher affinity TRAIL-R1 lacking N-glyc, suggesting that this sugar modification may have evolved as a counterstrategy to prevent receptor inhibition by UL141. Altogether our findings demonstrate that N-glyc of TRAIL-R1 promotes TRAIL signaling and restricts virus-mediated inhibition

    Elaboration d'une sonde optique fibrée à résolution micrométrique : application à l'autofluorescence des cellules de la peau

    No full text
    Les phénomènes de fluorescence sont utilisés dans un nombre toujours croissant d'applications. Dans les domaines biologiques et médicaux, les investigations cellulaires des phénomènes de fluorescence connaissent un certain développement ces dernières années. Malheureusement, les outils d'investigation mis à disposition dans ce type d'étude, comme le microscope confocal à fluorescence, sont souvent mal adaptés pour des explorations in vivo. Cet état de fait a motivé la recherche très ambitieuse d'une nouvelle méthode d'investigation. Nous proposons une approche innovante basée sur l'utilisation d'un capteur miniature fibré de 2 mm de diamètre, associé à un système de balayage approprié. L'approche résolument nouvelle envisagée a nécessité le développement d'un système de balayage miniature, inédit. Ce système pallie les problèmes de vitesse de balayage et d'encombrement qui sont les principaux travers des systèmes existants. Avant la réalisation du capteur fibré, une première étape de simulation a permis d'optimiser sa conception et ses performances. Le travail de caractérisation qui a suivi a démontré que la résolution latérale de notre sonde est de 2 pm sur les images en intensité de fluorescence et une résolution temporelle de 1 ns sur les images en temps de déclin de fluorescence. Cette caractérisation a été réalisée au travers de l' exploration d'échantillon de test et d'échantillons biologiques (feuilles de plantes). Les échantillons tests que nous avons élaborés par photolithographie sont constitués de structures microscopiques fluorescentes. Ces structures sont composées de polymère dopé avec un fluorophore naturellement présent dans les cellules: la protoporphyrine IX. Nous avons choisi d'étudier cette molécule en raison de son grand intérêt en dermatologie, où elle agit comme marqueur dans certaine lésions de l'épiderme, notamment certains cancers. Ce travail de recherche se poursuit finalement sur l'étude in-vivo de la fluorescence de la peau.BESANCON-BU Sciences Staps (250562103) / SudocSudocFranceF

    Microsystèmes et microcapteurs pour les sciences du vivant

    No full text
    BESANCON-BU Sciences Staps (250562103) / SudocSudocFranceF

    Instrumentation optique pour la mesure des périkymaties de la couronne dentaire

    No full text
    BESANCON-BU Sciences Staps (250562103) / SudocSudocFranceF

    Dispositif de stimulation olfactive pour l'investion en imagerie par résonance magnétique fonctionnelle

    Get PDF
    L Imagerie par Résonance Magnétique fonctionnelle (IRMf) a connu un grand essor ces deux dernières décennies. En effet, l arrivée sur le marché d IRM de haute résolution (5 Teslas et dernièrement 7 Teslas) a permis l étude des mécanismes cérébraux. Le travail de recherche de cette thèse s inscrit dans ce contexte.Il s agit de développer une instrumentation pour des études objectives du comportement cérébral sous l effet de stimuli. Nous nous sommes intéressés à l étude de l olfaction. Nous avons conçu et réalisé un stimulateur olfactif à six canaux, synchronisable avec la respiration et contrôlable par ordinateur. L originalité de notre travail réside en la modularité de notre appareil, qui en fait un dispositif adaptable aux besoins des études. Nous proposons une approche innovante pour modifier l intensité des stimulations délivrées : la Modulation de Largeur d Impulsion (MLI).Cet appareil a été utilisé dans plusieurs études en IRMf. L efficacité de la MLI est mise en évidence dans une étude psychophysique décrite dans ce manuscrit.The Magnetic Resonance Imaging (fMRI) has been developing for twentyyears. Indeed, the marketing of high-resolution MRI (5 Tesla and 7 Tesla recently)allowed the study of brain mechanisms. The research work of this PHD was todevelop instrumentation for objective studies of brain behavior during a sensorystimulation. We are interested in the study of olfaction. We have designed and builta six-channel olfactometer, synchronized with breathing and controlled by computer.The originality of our work lies in the modularity of our device, which makes itadaptable to a wide range of studies. We also propose an new method to changethe intensity of stimulation delivered : the Pulse Width Modulation (PWM). Thisdevice has been used in several studies in fMRI. The effectiveness of the PWM ishighlighted in a psychophysical study described in this manuscript.BESANCON-BU Sciences Staps (250562103) / SudocSudocFranceF
    corecore